MEMSnet Home: MEMS-Talk: Sticking of fragile MEMS structures
Sticking of fragile MEMS structures
2004-10-24
Oudalov, A. (EL)
2004-10-25
Kirt Williams
2004-10-26
Jan Lichtenberg
2004-10-25
HAN Anpan
2004-10-25
Marx, David L ( GE Infrastructure )
2004-10-25
[email protected]
2004-10-26
Xu Zhu
2004-10-27
Yianni Tousimis
Sticking of fragile MEMS structures
Oudalov, A. (EL)
2004-10-24
Hi there,

I am trying to release a comb drive structure etched by deep reactive ion
etching (DRIE) on a SOI silicon wafer. I try to make very thin gaps between
the comb drives to have a large electrostatic force. Since the spring
constant of my supporting structure is small I get problems when I release
the chips in buffered hydro-fluoric acid (BHF). The adjacent combs stick
permanently and the device is broken. I also tried critical point drying,
the yield is little higher but not satisfactory. Who knows about another,
more gentle method to release my combs?

Thanks a lot,
Alexander