DC-bias shift in the presence of strong vibration in MEMS
Mike Falck
1998-10-26
accelerometers. (Pedulous Rectification?)
This is a multi-part message in MIME format.
------=_NextPart_000_0016_01BE00B6.7C745840
Content-Type: text/plain;
charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable
We are observing a DC-bias shift in the presence of strong vibration in =
the non-sensitive axis of a MEMS accelerometer. We have heard that it =
is or could be related to a phenomenon called "Pedulous Rectification". =
We would like any information regarding this issue.
The experiment we have performed is to take a MEMS accelerometer and =
vibrate it in its non-sensitive axis from 50Hz-2KHz at 1.5g peak sine =
wave. The DC-offset or bias will change as much as 60mV at certain =
frequencies. The sensors we are using have a 0g bias at ~2.5V and have =
a sensitivity of 2V/g.
Since we are using the accelerometers in a precision tilt application =
the 60mV appears as a significant error.
Thanks in advance,
Mike Falck
Crossbow Technology
Ph: (408)965-3315.
Email: [email protected]
------=_NextPart_000_0016_01BE00B6.7C745840
Content-Type: text/html;
charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable
We are observing a DC-bias shift in =
the presence=20
of strong vibration in the non-sensitive axis of a MEMS =
accelerometer. We=20
have heard that it is or could be related to a phenomenon called =
"Pedulous=20
Rectification". We would like any information regarding this=20
issue.
The experiment we have performed is =
to take a=20
MEMS accelerometer and vibrate it in its non-sensitive axis from =
50Hz-2KHz at=20
1.5g peak sine wave. The DC-offset or bias will change as much as =
60mV at=20
certain frequencies. The sensors we are using have a 0g bias at =
~2.5V and=20
have a sensitivity of 2V/g.
Since we are using the =
accelerometers in a=20
precision tilt application the 60mV appears as a significant =
error.