MEMSnet Home: MEMS-Talk: Ni adhesion to Si
Ni adhesion to Si
2010-09-14
Salam Gabran
2010-09-14
Ruiz, Marcos Daniel (SENCOE)
2010-09-15
Ned Flanders
2010-09-15
[email protected]
2010-09-15
Denis Petrov
2010-09-15
Xiaohui Lin
2010-09-15
George P. Watson
2010-09-20
Salam Gabran
Ni adhesion to Si
Denis Petrov
2010-09-15
Hi!

Ni has bad adhesion to Cr but good to gold. So, you could try to
sputter first say 15 nm of Cr followed by 80 nm of Gold. And then your
Ni.

Regards,

Denis

2010/9/15  :
> Try 10nm of Cr as an intermediate layer between Ni and Si.
>
> Cheers,
>
> Marcel
>
>
> Quoting Salam Gabran :
>
>> Hi Guys,
>>
>> I am trying to sputter deposit Ni on Si followed by annealing at a different
>> temperature (350, 450 degreesC). The nickel is 30nm and 200nm.
>> During annealing, the Ni film peals off, it should be due to thermal
>> stresses during deposition.
>>
>> Any clue how this can be resolved ?
>>
>> kind regards
>>
>> Salam R. Gabran, MASc.
>> Research associate, PhD. Candidate
>> Center for Integrated RF Engineering
>> (CIRFE) Group
>> ECE Dept., University of Waterloo

--
День

The Band "Kater Fritz"

http://www.myspace.com/thebandkaterfritz
reply
Events
Glossary
Materials
Links
MEMS-talk
Terms of Use | Contact Us | Search
MEMS Exchange
MEMS Industry Group
Coventor
Harrick Plasma
Tanner EDA
MEMStaff Inc.
University Wafer
Process Variations in Microsystems Manufacturing
The Branford Group