Dear Mr. Daven Chou
You can use switch capacitor readout circuit. Pl. refer Y. Y. Qiu
in 'Sensors and Actuators-A', Vol 92 (2001) Page 80-87 to learn more
details.
RAJKUMAR
Semiconductor Complex Limited.
Sector-72, Industrial Area, SAS Nagar.
Mohali (Chandigarh), INDIA
Phone: 91-172-2237401 to 10 (extn. 576, 505)
Fax: 91-172-2236378
> Message: 5
> Date: Wed, 10 Mar 2004 17:30:30 +0800
> From: "daven chou"
> Subject: [mems-talk] new circuit interface in integrated humidity
> sensor
> To:
> Message-ID:
> Content-Type: text/plain; charset="gb2312"
>
> Dear everyone:
> I wanna get the latest information about the circuit interface about
capacitive MEMS humidity sensor .I used polyimide as a sensitivity layer.
> Thanks a lot!
> yours sincerely
> Daven Chou
>
> ------------------------------
>