Cleaning gases? Do you always have to use cleaning gases? Is this just
to remove particulates? I suppose we would use a flourine chemistry and
we have only one processing chamber that is contained by a glove box.
Thanks,
Mike
>>> wstonas@surromed.com 02/04/02 09:15AM >>>
Hi Mike,
What cleaning gases are you using for your chamber clean. Certain
cleaning
gases are incompatible with process gases. If your cleaning gases
contain
chlorine or fluorine molecules, many places require a wet scrubber and
burn
box combination. In addition how many chamber do you want connect to
the
system? If you want to connect several chamber to the same system, you
need to
make sure you have seperate entrance ports to the system as well as
nitrogen
purge curtain at the entrance port.
Sincerely,
Walter Stonas
Process Development Engineer
-----Original Message-----
From: Michael Martin [mailto:michael.martin@louisville.edu]
Sent: Friday, February 01, 2002 9:18 AM
To: mems-talk@memsnet.org
Subject: [mems-talk] Clarification on the Burn Box Question
Hi,
We intend to PECVD deposit SiO2, Silicon Nitride and amorphous
silicon
so we will likely be using SiH4, N2O, and NH3. Can anyone tell me what
sort of burn box we will require?
Thanks,
Mike
_______________________________________________
mems-talk@memsnet.org mailing list: to unsubscribe or change your list
options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk
Hosted by the MEMS Exchange, providers of MEMS processing services.
Visit us at http://www.mems-exchange.org/
_______________________________________________
mems-talk@memsnet.org mailing list: to unsubscribe or change your list
options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk
Hosted by the MEMS Exchange, providers of MEMS processing services.
Visit us at http://www.mems-exchange.org/