We are trying to connect chromium contacts of a structurated glass
plate on a PCB connector with the ZSP8150-FP film from AI Technology
Inc. The contacts are 800 microns large, separated every 1 mm. Until
now, we did not succed to have a good conductivity. We tried 80=B0C, and
150=B0C, and applied different pressure strength.
Does anyone have some experience with unidirectionally conductive film
adhesive (from AIT or other companies) ?
Best regards.
_/ _/ _/ Bruno Guerard
_/ _/ _/ email:guerard@ill.fr
_/ _/ _/ Institut Laue-Langevin
_/ _/ _/ B.P.156, 38042 Grenoble Cedex 9,=
France
_/ _/_/_/_/ _/_/_/_/ tel:(33) 76.20.72.77 fax:(33)76.20.77.00