Hi Sampo,
well, dilution minimizes the etch rate, as higher concentration enhances it.
About linearity I'm not quite sure.
Antje
Sampo Tuukkanen schrieb:
> Hi,
>
> how can I etch gold slowly (~100 nm/min)?
> Can I slow etching by diluting etch-solution (4g KI / 1g I2 / 40ml H2O),
> which etches 500-1000 nm/min?
> If so, does the etch-rate reduce linearly with consentration of KI and I2?
>
> -Sampo Tuukkanen, University of Jyväskylä, FINLAND
>
> _______________________________________________
> MEMS-talk@memsnet.org mailing list: to unsubscribe or change your list
> options, visit http://www.memsnet.org/mailman/listinfo/mems-talk
> Hosted by the MEMS Exchange, providers of MEMS processing services.
> Visit us at http://www.memsnet.org/